PLUSME A1A3 - Earth-Rite PLUS ATEX, thiết bị khử tính điện, Newson Gale Việt Nam 

Earth-Rite PLUS ground monitoring unit
- Zone 1/21, ATEX and IECEx certification, SIL 2.
- Copper-free cast aluminium enclosure.
- RED/pulsing GREEN indication LEDs.
- Intrinsically safe monitoring to =10 Ohm.
- 2 off interface relay contacts.
- Power requirement 110/120 or 220/240 V AC.
- Supplied with 1 pair of handles for opening and closing of the enclosure lid.
2 pole large heavy duty stainless steel clamp c/w 10 m Hytrel sheathed spiral cable.
- Junction box with quick connection and universal stowage pin.
- Zone 0/20, ATEX and FM certification

System options

Newson Gale supplies a range of product options that enhance the control and general safety of transfer processes and aid engineers with system installations and routine system service checks. Contact Newson Gale or your local Newson Gale representative for more information on the range of options available.

VESM02 Retractable Cable Reel 

Product Code: VESM02

The VESM02 Retractable Cable Reel is supplied for grounding system installations where customers want to ensure the grounding clamp and cable are returned to the static grounding system by operators and drivers on completion of the product transfer process. The VESM02 Reel can be used in conjunction with the Earth-Rite RTR, Earth-Rite MGV and Earth-Rite PLUS. 

> Certified for ATEX Zone 1 and 21 hazardous areas. ® 

> Self-retracting with up to 15 m (50 ft.) of Hytrel protected cable. 

> Silver plated ultra low resistance slip ring contacts. 

> ATEX - II 2 GD T6

Ex Strobe Light 

Product Code: STROBE11/A

The strobe light is mounted in an elevated position and when the equipment is correctly grounded, flashes continuously informing personnel that a transfer process is underway and is protected from the static hazard. The strobe light can be used in conjunction with the Earth-Rite RTR and Earth-Rite PLUS. 

> 115 V / 230 V AC and 24 V DC options. 

> II 2G Ex d IIC T5 (Ta. -50°C to +40°C). 

> II 2D Ex tD A21 IP67 T125°C based on max. Ta. 70°C. 

Universal Resistance Tester

Product Code: URT

The URT is designed to provide owners of Newson Gale Earth-Rite and ® Bond-Rite static grounding systems with a means of regularly testing the grounding settings for their system on a routine basis.

Periodic testing with the URT verifies that the grounding system’s GO/NO GO settings are working in compliance with the recommendations of:

NFPA 77: “Recommended Practice on Static Electricity.”

IEC 60079-32-1: “Explosive atmospheres. Part 32-1: Electrostatic hazards, guidance.”

The easy to use tester consists of a pair of switches that enable an electrician to set up the resistance level at which the grounding system should be working and conduct a PASS / FAIL test at the required setting.

Earth-Rite and Bond-Rite products that can be tested with the URT:

> Earth-Rite PLUS ®

> Earth-Rite FIBC (both 10 meg-ohm and 100 meg-ohm variants)

> Bond-Rite CLAMP ® 

> Bond-Rite EZ

> Bond-Rite REMOTE ® 

> OhmGuard (both 10 ohm and 100 ohm variants).

Installer’s Kit

Product Code: ER2KITA

This kit provides installation engineers with the necessary Ex (d) enclosure glands (x5) and system cable (x3) required to complete an Earth-Rite RTR or Earth-Rite PLUS installation as specified in the system installation manuals. Two of the glands cater for both armoured and non-armoured cable diameters ranging from 9 mm to 13.5 mm. Three glands cater for IS current carrying non-armoured cable with cable diameters ranging from 4 mm to 8.4 mm. * For areas not requiring IIC apparatus.

> Ex (d) IP68 glands (x2) for armoured cable 9 mm to 13.5 mm Ø.*

> Ex (d) IP68 glands (x3) for non-armoured cable 4 mm to 8.4 mm Ø.*

> 3 m of 2 core conductor cable (x1) to connect system enclosure to clamp stowage box.

> 1 m of solid green earth loop cable (x2), with Ex (d) glands, PCB connectors and 10 mm bolt eyelets attached.

> 1 pair of handles to aid opening and closing of the enclosure lid.

Sun Shield

Product Code: ER2/SH

Designed for operating environments subject to intense sunlight, the ERII Sun Shield prevents direct sunlight hitting the indicators on the Earth-Rite RTR and Earth-Rite PLUS static grounding systems.

The Sun Shield casts a shadow over the indicators during peak sun light hours so that operators can easily view the ground status indicators. The shield is constructed from stainless steel and can be fitted to any installation in a matter of minutes.

2-Pole Surface Mountable connector

Product Code: SMC

With this assembly operators tasked with earthing mobile process equipment will have a dedicated earthing point to attach the easy to use screw thread connector. The ‘plug and play’ connector can interface with all Newson Gale 2 core systems to provide earth monitoring capability on a wide range of mobile processes and equipment where generic earthing clamps cannot be used.

The conical shape design prevents powder deposit build up over time and aids in clean down operations.

> Made using Stainless Steel 304 with Viton O-Rings

> IP 66

> -40˚C to 60˚C

> Various lengths of straight or spiral Hytrel cable available.